How to measure
- Measure the room's length, width and ceiling height. Heat fills the whole volume, so height matters.
- Decide the temperature rise: the temperature you want inside minus the coldest it usually gets outside — or in the space next door, for a room surrounded by heated house. 68 °F inside on a 38 °F day is a 30 °F rise.
- For a garage, basement or addition, use the outdoor or ground temperature, not the house temperature.
- Pick the insulation level: 'well insulated' for newer construction with good windows, 'poor' for an uninsulated garage or a drafty room with single-pane glass.
How the heater size calculation works
Volume (cu ft) = length × width × height Heat (BTU/h) = volume × temperature rise (°F) × insulation factor Factor = 0.09 well insulated · 0.133 average · 0.2 poor Watts = BTU/h × 0.293 Heaters = watts ÷ 1,500, rounded up
Heat leaks out through walls, windows, ceiling and air gaps faster the bigger the room and the bigger the temperature difference. This rule of thumb rolls all of that into one insulation factor per cubic foot per degree. It's an approximation used for sizing space heaters — not a room-by-room heat-loss calculation.
0.133 is the commonly quoted factor for average construction. We use 0.09 for a tight, well-insulated room and 0.2 for a poorly insulated one. Metric inputs are converted: a 1 °C rise is a 1.8 °F rise.
One watt is 3.412 BTU/h. As a cross-check, the result also shows the quick 10 watts per square foot rule for an average room with 8 ft ceilings.
Worked example
A 12 × 12 ft bedroom with an 8 ft ceiling and average insulation, kept at 68 °F when it's 38 °F outside.
- Volume: 12 × 12 × 8 = 1,152 cu ft
- Temperature rise: 68 − 38 = 30 °F
- Heat: 1,152 × 30 × 0.133 = 4,597 BTU/h
- Watts: 4,597 × 0.293 = 1,347 W
- Cross-check: 144 sq ft × 10 W = 1,440 W
One 1,500 W heater covers it. On a colder night, with a bigger temperature rise, it will run longer and may not keep up.
Reading your result
Watts and BTU/h are the same thing in different units — heater boxes in the US usually list both. Every electric resistance heater turns 1 W of electricity into 3.412 BTU/h of heat, so a '1,500 W' heater is about 5,100 BTU/h whatever its shape.
If you need more than 1,500 W, one plug-in heater won't do it. Use two on separate circuits, or a hardwired 240 V wall or baseboard heater sized to the result.
A big gap between the main result and the 10 W per sq ft cross-check usually means a high ceiling, a large temperature rise or poor insulation — check those inputs.
Assumptions
- The insulation factor stands in for real wall, window and ceiling heat loss and air leakage. Rooms with a lot of glass, an exterior door or a cold slab floor need more.
- The temperature rise is the worst case you want to cover. Sizing for the coldest night means the heater cycles off on milder ones.
- 1,500 W is the most a US plug-in heater draws: 12.5 A at 120 V, which is 80% of a standard 15 A circuit.
Unit conversions use exact definitions (1 in = 25.4 mm, 1 US gal = 3.785 L). See the calculation methodology for rounding rules.
When to call a professional
- Hardwired 240 V heaters, garage unit heaters and anything on a new circuit should be installed by a licensed electrician.
- For heating a whole home, an addition or a converted space as a main heat source, have an HVAC contractor do a Manual J heat-loss calculation.
- Gas, propane and kerosene heaters need proper venting and a carbon monoxide alarm. Unvented heaters are banned in some states and rooms.
Frequently asked questions
What size heater do I need for a 12 × 12 room?
With 8 ft ceilings and average insulation, about 1,350–1,450 W (4,600–4,900 BTU/h) for a 30 °F rise. One 1,500 W heater is enough. A cold garage or poor insulation can double that.
How many square feet does a 1,500 W heater heat?
About 150 sq ft as a main heat source using the 10 W per sq ft rule, more if the room is well insulated or you only need to take the chill off.
Can I run two space heaters on one outlet?
No. Two 1,500 W heaters draw about 25 A — well over a 15 or 20 A circuit. Put them on separate circuits, and never use an extension cord or power strip.
How many BTU is 1,500 watts?
1,500 × 3.412 = about 5,118 BTU per hour.