Insulation Calculator

Enter the area, where it is and your climate zone. You'll get the bags of batts or blown-in insulation to buy from the manufacturer's coverage chart, and the R-value ENERGY STAR recommends for your zone.

Measurements

Where?

Attic or floor: length × width. Walls: length × height, less windows and doors.

IECC climate zone for US counties — look yours up on the ENERGY STAR or DOE climate zone map.

Insulation type
Waste allowance

Rule of thumb for batts cut around framing, pipes and wiring.

Your estimate

You need 12 bags of R-30 insulation.

1,050 sq ft with waste ÷ 88 sq ft per bag.

Area
1,000 sq ft
Waste allowance
5%
Area with waste
1,050 sq ft
Coverage per bagJohns Manville fact sheet
88 sq ft
Bags to buy
12 bags

R-value

You're installing
R-30
ENERGY STAR recommendsZone 5, uninsulated attic
R-60
  • That's below the ENERGY STAR recommendation of R-60 for this zone. In an attic you can layer a second run of unfaced batts across the first, or blow loose fill over existing insulation.
  • Seal air leaks around pipes, wires, recessed lights and the attic hatch before insulating — insulation doesn't stop air movement.

Next step

Closing up the walls?

Work out drywall sheets, mud and tape for the same room.

Drywall calculator

Also useful

Sizing a heater afterwards?

Better insulation lowers the heat a room needs.

Heater size calculator

How to measure

  1. Attic floor or crawlspace ceiling: measure length × width of the space you're insulating.
  2. Walls: measure each wall's length × height and subtract windows and doors.
  3. Find your IECC climate zone on the ENERGY STAR or DOE climate zone map (zones 1–8 across the US).
  4. Check what's there now: if the attic already has 3–4 in, tick the box — the recommendation changes.

How the insulation calculation works

Batt bags  = area × (1 + waste) ÷ sq ft per bag
Blown bags = area ÷ maximum coverage per bag
Blown depth ≥ the label's minimum thickness for that R-value

Every bag lists how many square feet it covers. Batts: pieces per bag × batt size (an R-30, 24 × 48 in bag of 11 pieces covers 88 sq ft). Loose fill: a chart of bags per 1,000 sq ft and minimum thickness for each R-value.

Blown-in only reaches its rated R-value when you install both the bag count and the minimum thickness from the chart. That's why this calculator never converts depth to R-value on its own.

Worked example

A 1,000 sq ft attic in climate zone 5, insulated with R-30 batts 24 in wide, with 5% waste; then the same attic blown to R-49.

  1. ENERGY STAR for zone 5, uninsulated attic: R-60 (R-49 when topping up 3–4 in)
  2. Batts: 1,000 × 1.05 = 1,050 sq ft ÷ 88 sq ft per bag = 11.9 → 12 bags
  3. Blown-in R-49 (AttiCat chart): 1,000 ÷ 39.9 sq ft per bag = 25.1 → 26 bags, at least 17 in deep

12 bags of R-30 batts — a single layer is below the R-60 recommendation, so plan a second layer — or 26 bags of blown-in for R-49.

How much extra to allow

Batts get trimmed around wiring, pipes, blocking and odd bays. Blown-in has no offcuts but must reach the full depth everywhere, including the edges.

SituationAllow
Open attic, regular joists0–5%
Walls with many outlets and pipes5–10%

Reading your result

Bags to buy is the shopping list. For blown-in, mark the minimum depth on a few rulers stapled to the joists so you can see when you've reached it.

The R-value comparison tells you whether one layer is enough or a second layer is worth adding.

Assumptions

  • Recommended R-values are ENERGY STAR's retrofit table for wood-framed homes, based on the 2021 IECC (Table R402.1.3).
  • Batt coverage from the Johns Manville fact sheet; blown-in coverage from the Owens Corning AttiCat PINK data sheet. Other products differ — choose "Other" and use your label.
  • Batt bag coverage is the batt area; framing takes up a little of a wall, so this slightly over-buys rather than under-buys.
  • R-values are US units (ft²·°F·h/BTU); RSI = R × 0.1761.

Unit conversions use exact definitions (1 in = 25.4 mm, 1 US gal = 3.785 L). See the calculation methodology for rounding rules.

When to call a professional

  • Knob-and-tube wiring, vermiculite (which can contain asbestos), signs of moisture or mold, or recessed lights not rated for contact with insulation should be dealt with by a professional before insulating.

Frequently asked questions

How much insulation do I need in my attic?

ENERGY STAR recommends R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4–8 for an uninsulated attic, and R-25 to R-49 when adding to 3–4 in of existing insulation.

How many square feet does a bag of insulation cover?

It's on the label. A Johns Manville R-13 bag of 15 × 93 in batts covers 106.56 sq ft; an R-30 bag of 24 × 48 in batts covers 88 sq ft. Owens Corning AttiCat blown-in covers 68.5 sq ft per bag at R-30 and 39.9 sq ft at R-49.

How deep is R-49 blown-in insulation?

It depends on the product. Owens Corning AttiCat PINK needs at least 17 in for R-49, along with the chart's bag count. Cellulose reaches the same R-value at a different depth.

Can I put new insulation over old?

Usually, yes — if the old insulation is dry and not compressed. Lay unfaced batts across the joists or blow loose fill on top. Don't add a second vapor retarder (faced batts) on top of existing insulation.