How to measure
- Measure the slab inside the forms.
- Take the bar size and spacing from your plans or permit drawings.
- Set the edge distance — how far the grid stops short of the forms (3 in is common).
- Pick the stock length you'll buy: 20 ft bars mean fewer splices on large slabs, 10 ft bars fit in a car.
How the rebar calculation works
Bars one way = floor((width − 2 × edge) ÷ spacing) + 1 Pieces per run = 1 + ceil((run − stock) ÷ (stock − lap)) when run > stock Cut length = run + splices × lap Bars to buy = Σ cut lengths ÷ stock length, rounded up Weight = total length × weight per foot
Bars run both ways across the slab. Each run that's longer than a stock bar is spliced, and every splice overlaps by the lap length, so long slabs use more steel than their dimensions suggest.
Weights are ASTM A615 nominal values: #3 0.376, #4 0.668, #5 1.043 and #6 1.502 lb per ft. Metric bars use steel at 7,850 kg/m³.
Worked example
A 20 × 12 ft slab, #4 bars at 18 in each way, 3 in from the edges, from 20 ft bars.
- Runs: 20 ft − 6 in = 19.5 ft and 12 ft − 6 in = 11.5 ft — both fit a 20 ft bar, so no splices
- Bars along the length: floor(138 ÷ 18) + 1 = 8; along the width: floor(234 ÷ 18) + 1 = 14
- Total: 8 × 19.5 + 14 × 11.5 = 317 ft ÷ 20 = 15.9 → 16 bars
- Weight: 317 × 0.668 = 212 lb; 8 × 14 = 112 intersections to tie
Buy 16 bars of #4 rebar, 20 ft long — about 212 lb of steel.
Reading your result
The bars-to-buy row is your order. Add tie wire and chairs (or dobies) to hold the grid at mid-depth.
If a run needs a splice, stagger the splices so they don't all line up across the slab.
Assumptions
- Offcuts are reused for shorter runs; without that you may need a bar or two more.
- Lap length defaults to 40 bar diameters, a common rule of thumb. ACI 318 and CRSI make lap length depend on bar size, steel grade, concrete strength and spacing — use the length on your drawings.
- Spacing options are common values, not a design recommendation.
- Wire mesh: 5 × 10 ft sheets overlapped 6 in each way.
Unit conversions use exact definitions (1 in = 25.4 mm, 1 US gal = 3.785 L). See the calculation methodology for rounding rules.
When to call a professional
- Reinforcement for footings, foundation walls, structural slabs and anything carrying a building is specified by an engineer or the code tables your building department uses. This calculator counts steel for a layout you already have.
Frequently asked questions
How much does rebar weigh per foot?
#3: 0.376 lb, #4: 0.668 lb, #5: 1.043 lb, #6: 1.502 lb per foot (ASTM A615 nominal weights).
How much should rebar overlap?
It depends on the bar, steel grade and concrete. 40 bar diameters (20 in for #4) is a common rule of thumb, but the lap length on your plans governs.
How many rebar intersections do I need to tie?
A grid has one intersection per crossing — bars one way × bars the other way. Specs vary between tying every intersection and every other one.
Is wire mesh as good as rebar in a slab?
They do different jobs. 6 × 6 welded wire mesh mainly controls shrinkage cracks in light slabs; rebar adds more strength. Use what your plans call for.